- esmo semicon
- »
- HANDLING SYSTEMS
- »
- apollo – pick & place quad handler
apollo
A revolutionary pick & place device handler
Maximum energy efficiency, ultimate thermal performance, and flexible applications for semiconductor testing.
Quad handler with superior energy efficiency, ultimate temperature performance, unmatched reliability, effortless operation, and seamless transitions to cutting-edge products.
typical use cases
- Ultimate thermal performance & accuracy
- high volume /multisite engineering
- low & medium volume production
- high volume production for test times >5s
Discover a new era of efficiency and precision with Apollo – the new game-changer in the semiconductor testing.
Key Features (Highlights)
- Productivity: Up to 2,800 UPH @ 4s test time
- Flexibility: Supports QFP, QFN, SO, SOT, BGA and more | Tool-less kit changeover < 5 minutes
- Thermal Performance: –80 °C to +225 °C, ±0.5 °C stability
- Ease of Use: 23.8” multi-touch panel, intuitive HMI
Applications
- High-volume & multisite engineering
- Low & medium volume production
- High-volume production > 5s test time (Apollo Super Soak)
Technical Specifications
System & Performance:
- Single, dual, or quad site contacting
- Index time (4 devices): 0.85s
- Reuse of existing loadboards, no fixed socket pitch
Thermal Performance:
- Min. plunger: –80 °C (LN2) / –70 °C (e-chiller)
- Max. plunger: +225 °C
- Stability: ±0.5 °C
- Heat-up: +21 °C to +175 °C in 3 min
- Cool-down: +21 °C to –50 °C in 13 min (LN2 system)
Device Compatibility:
- Packages: QFP, QFN, SO, SOT, BGA and more
- Size range: 2.5 × 2.5 × 0.5 mm up to 125 × 120 × 10 mm
- Tool-less kit changeover < 5 minutes
Input / Output Options
- JEDEC tray, tube, tape, bowl, magazine
- Continuous load supported
- Bin configuration free, Pin1 orientation free
Interfaces
- RS232, TCP/IP, GPIB, TTL
Facility requirements I:
- Power supply:
Handler: 120V / 13A / 60Hz (Nema 5-15r or 5-20r receptacle)
Electric Chiller: 120V / 19A / 60Hz (Nema 5-20r receptacle)
* Separate 20 Amp circuit needed for E-chiller.
* Chiller requires Nema 5-20R wall receptacle. - Compressed Air:
1⁄4 Inch NPT Male threaded quick connect fitting supplied by customer (or alternative 1⁄4 Inch NPT male fitting)
*Also need female fitting on supply line Minimum 6 bar (87 psi) / Maximum 14 bar (203 psi)
Maximum Consumption:
• 50Nl/min during hot test
• 170Nl/min during LN2 cold test *including chamber purge
Must be clean, dry, oil-free air (CDA)
*Please ensure the dew point of the supply air is -60°C (-76°F) if cold testing will be performed or icing will occur.
Facility requirements II:
- Vacuum Supply:
1⁄4 Inch NPT Female quick connect fitting supplied by customer (or alternative 1⁄4 Inch NPT female)
*Also need male fitting on supply line
Minimum vacuum 200 mbar
Not needed with onboard vacuum pump option - LN2:
3⁄8 Inch NPT Female LN2 supply connection (provided with LN2 option)
Minimum 1.5 bar (22 psi)
Maximum 4.0 bar (59 psi)
*For pressures over 3.5 bar, a regulator is required
*Please refer to 0101.30.00.0049 below for esmo regulator & relief valve assembly (if needed, based on incoming supply pressure)
Typical consumption rate (steady state) 3.0 l/h
Peak consumption rate (cooldown phase) 8.5 l/h
Why Choose Apollo?
- Superior energy efficiency
- Future-proof (AMR/AGV ready)
- High throughput → fast ROI
- Best-in-class thermal accuracy
Sounds interesting? Contact us!
esmo semicon
Rosenheim / Germany
Phone +49 (8031) 233 88 0
apollo(at)esmo-ag.com